B-2 SPARC Enterprise Mx000 Servers XSCF User’s Guide • August 2009
â–  To check whether a fault occurred if a message is output to the domain console
and XSCF console. (See Appendix A.)
â–  To check whether the information is fault information if it was reported to the
previously registered email address.
â–  To check whether the information is fault information if TRAP occurred in the
SNMP manager.
Using the showlogs(8) Command to Confirm a Fault
1. Specify the error option on the XSCF Shell and perform the showlogs(8)
command to reference the XSCF error log.
(The layout of the command example is subject to change without previous notice
for functional improvement.)
In the example above, the following items are displayed:
â–  Time at which each problem was logged (Date). This date is indicated in local
time.
â–  DIAGCODE that the field engineer and authorized service personnel use for
troubleshooting (Code). The user is requested to inform the field engineer and
authorized service personnel of this Code. This is useful in settling the problem at
an early stage.
â–  Fault level of the component (Status). One of the following items is displayed:
â–  Time at which each problem occurred (Occurred). This is indicated in local time.
â–  Replacement component (FRU) that is probably faulty. A comma (,) separates two
suspect components displayed. For additional suspect components, an "*"
(asterisk) is displayed after the comma (,). Each component is displayed
XSCF> showlogs error
Date: Mar 30 15:45:31 JST 2005 Code: 00112233-44556677-8899aabbcceeff00
Status: Warning Occurred: Mar 30 15:45:26.000 JST 2005
FRU: PSU#1,PSU#2
Msg: ACFAIL occurred (ACS=3)(FEP type = A1)
Date: Mar 30 17:45:31 JST 2005 Code: 00112233-44556677-8899aabbcceeff00
Status: Alarm Occurred: Mar 30 15:45:26.000 JST 2005
FRU: PSU#1,PSU#2,*
Msg: ACFAIL occurred (ACS=3)(FEP type = A1)
Alarm: The relevant component failed.
Warning: Some subcomponents in the relevant component failed or degraded.

Table of Contents

Other manuals for Sun Microsystems Sun SPARC Enterprise M4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems Sun SPARC Enterprise M4000 and is the answer not in the manual?

Sun Microsystems Sun SPARC Enterprise M4000 Specifications

General IconGeneral
BrandSun Microsystems
ModelSun SPARC Enterprise M4000
CategoryServer
LanguageEnglish

Related product manuals