Engine Electrical Devices: 1C-6
IAT Sensor Removal and Installation
B815H21306013
Removal
1) Remove the air cleaner box. Refer to “Air Cleaner
Box Removal and Installation in Section 1D
(Page 1D-6)”.
2) Remove the IAT sensor (1) from the air cleaner box.
Installation
Install the IAT sensor in the reverse order of removal.
Pay attention to the following point:
• Tighten the CMP sensor screw (1) to the specified
torque.
Tightening torque
IAT sensor mounting screw (a): 5.5 N·m (0.55 kgf-
m, 4.0 lb-ft)
IAT Sensor Inspection
B815H21306014
Refer to “DTC “C21” (P0110-H/L): IAT Sensor Circuit
Malfunction in Section 1A (Page 1A-52)”.
Inspect the IAT sensor.
NOTE
IAT sensor resistance measurement method
is the same way as that of the ECT sensor.
Refer to “ECT Sensor Inspection (Page 1C-
5)”.
CAUTION
!
• The IAT sensor operative temperature
range is –30 – 120 °C (–22 – 248 °F).
• Do not heat the oil up to 120 °C (248 °F) or
more for this inspection.
IAT sensor specification
AP Sensor Inspection
B815H21306015
Refer to “DTC “C22” (P01450-H/L): AP Sensor Circuit
Malfunction in Section 1A (Page 1A-57)”.
AP Sensor Removal and Installation
B815H21306016
Removal
1) Remove the front seat. Refer to “Exterior Parts
Removal and Installation in Section 9D (Page 9D-
14)”.
2) Disconnect the coupler and remove the AP sensor
(1).
Installation
Install the AP sensor in the reverse order of removal.
TO Sensor Inspection
B815H21306017
Refer to “DTC “C23” (P1651-H/L): TO Sensor Circuit
Malfunction in Section 1A (Page 1A-64)”.
1
I815H1130012-01
(a)
1
I815H1130013-01
Temperature Standard resistance
20 °C (68 °F) Approx. 2.58 kΩ
80 °C (176 °F) Approx. 0.28 kΩ
120 °C (248 °F) Approx. 0.09 kΩ
1