SERVICING INFORMATION 20-19
*5
*9
*4
*6
*7
*3
*2
*1
*8
1 Ignition coil/plug cap *2
Bind the regulator/rectifier lead wire and magneto lead
wire with the clamp. Set the tip of the clamp inside.
2 TP sensor lead wire *3 The coupler of ignition coil/plug cap faces backward.
3 Condenser lead wire *4
Clamp the wiring harness at the gray taping. Set the
tip of the clamp inside.
4 Breather hose *5
Bind the ECT sensor lead wire, condenser lead wire
and TP sensor lead wire with the clamp. Set the tip of
clamp downward.
5 Engine stop switch lead wire *6
Pass the service coupler lead wire inside of the
bracket.
6 GP switch lead wire *7
Tighten coupler bracket bolt together with earth
branch wire of harness. Caulk the end of earth termi-
nal. (Bend flat part of earth terminal toward vehicle.)
a 90° – 110° *8 Bend the clamp twice.
*1
Place engine stop switch lead wire on hot
starter cable and bind them together with
the clamp. Set the tip of the clamp left side.
*9
Bind the ECT sensor lead wires, condenser lead wire
and TP sensor lead wire with the clamp. Set the tip of
clamp backward inside.