Annex C Messages of DUT-E CAN data transfer protocol
DUT-E fuel level sensors. Operation manual. Version 8.1
© Technoton, 2020 110
Table C.1 continued
#
Message name
Message parameters
Message content
Broadcast interval
Data length
Extended data page
(EDP)
Data page (DP)
PDU format (PF)
PDU specific (PS)
Default priority (P)
Parameter
group number
(PGN)
Initial
position
Length
Valuable data
Suspect
Parameter
Number
(SPN)
SAE J1939
4
PGN 65226
Active
Diagnostic
Trouble Codes
(DTC)
1 s
Vari
able
-
0
254
202
6
65226
(0XFECA)
1
7-8 bits
Reserve
987
5-6 bits
624
3-4 bits
623
1-2 bits
1213
2
7-8 bits
3041
5-6 bits
3040
3-4 bits
3039
1-2 bits
3038
3-4
2 bytes
SPN 523000 (
see table C.2
)
16 high valuable bits
1214
5
6-8 bits
SPN 523000 (
see table C.2
)
3 low bits
1-5 bits
FMI malfunction codes
(see table C.2)
1215
6
8 bit
Reserve. Value equals 0
1706
1-7 bits
Counter.
Value is 127 if counter is
used.
Value varies from 0 to 126
if counter is not used
1216
5
PGN 65276
Dash display
1 s
8
0
0
254
252
6
65276
(0xFEFC)
1
1 byte
Reserve
80
2
1 byte
Fuel level
96
3
1 byte
Reserve
95
4
1 byte
99
5-6
2 bytes
169
7-8
2 bytes
-
6
PGN 65279
“Operator
indicators”
10000
ms
2
6
0
254
255
6
65279
(0xFEFF)
1.1
2 bits
Water in Fuel Indicator
(1 yes; 0 no)
97
1.3
2 bits
Operator Shift Prompt
5675
2.1
3 bits
Driver Warning System
Indicator Status
5825
2.4
3 bits
Emission Control System
Operator Inducement
Severity
5826
the bytes are not used.