EasyManua.ls Logo

Tektronix 453 - Page 146

Tektronix 453
246 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-
,.....,..,
"""""'
,.,,,,
1.
Pull
the
intermediate
sec-
ti
on
of each slideout track
out
to its
fully extended
position.
2.
Insert
the
chassis
sections
(on
instrument)
into
the
intermediate sedions.
3.
Press both stop latches
and
push
the
instrument into
the
rack until
the
latches
snap
into
the
stop latch
holes.
4.
Connect
the
power
the power source.
5.
Again press
the
stop
latches
and
push
the
in-
strument all
the
way
into
the
rack.
6.
To
secure
the
Type R453
to
the
rack,
insert the 4
securing screws
(with
fin-
ishing washers
and
teflon
washers) through the slots
in
the
instrument
front
panel
and
screw them into
the front rails of
the
rack.
1. Remove the securing
and
washers.
2.
Pull the instrument outward
until the stop latches
snap
into the stop latch holes.
3.
Disconnect
the
power cord.
4. Press both stop latches
and
pull the instrument out
of
the rack.
Rackmounting-Type
453/R453
!Al
m
{C)
Fig.
6-9.
Procedure
for
inserting or removing the instrument after the slideout tracks
have
been installed.
©
6-7

Table of Contents