SYSTEM MAINTENANCE AND SOFTWARE UPDATE
CHAPTER 7
104
ECOTEL 3G 16.1. Revised: 1 March 2011.
The traps for the IP interfaces are also generated in ascending order according to the following list:
If more than one pppoe<x> profile is configured, the number will also increase.
Bear in mind that the keyword ALARM must be entered in the appropriate PRI, BRI or mobile port’s Subscriber line
in the pabx.cfg. The MIBs (Management Information Bases) are included on the product CD in the folder MIB. The
module name snmpd.tz0 must have the ending tz0!
The following settings are possible in the section [snmpd]:
Table 7.5 Traps for IP Interfaces
Port Number Interface
0 Ethernet 1
1 Ethernet 2
2Loopback
3 xppp= (if used)
4 pppoe= (if used)
Table 7.6 Settings in the Section [snmpd]
Parameter Definition
Port=<port> Defines the target port for the
get service (default 161). The port for the
trap server is fixed at 162.
TrapServer=<ip addr> Enter the SNMP trap server’s IP address. Example for listing more than
one:
TrapServer=192.168.0.10 192.168.0.12
Community=<password> Enter a password for a community (group). The default password is
public.
The current implementation evaluates the configured password only
when sending a trap. GET requests use the default value.