ONLINE TRAFFIC MONITOR
CHAPTER 11
195
ECOTEL 3G 16.1. Revised: 2011.
11 ONLINE TRAFFIC MONITOR
The Online Traffic Monitor allows you to collect and monitor statistics and call detail records (CDRs). The following
functions are possible with this feature package:
ASR calculation
Generation of CDRs
Generation of online CDRs using e-mail
11.1 ASR CALCULATION AND RESETTING STATISTIC VALUES AND
COUNTERS
When these functions are configured in the pabx.cfg file, the following statistic values are calculated for the entire
system at a defined time and are copied into a file in the following order:
Day and time of entry
System name
Number of connected calls followed by the number of total calls in parentheses
Number of minutes termintated
ASR1: ratio of total calls to connected calls disconnected by the A party
ASR(ext): external ASR for the traffic source
ASR(int): internal ASR for the ECOTEL
ACD: average call duration
Example: The following example shows how the statistics appear in the file into which they are copied:
Set the time using the following syntax: <
hh:mm>. If ?? appears instead of a specified hour (e.g. ??:mm), the
ASR is written into the asr.log file once every hour.
You can set
<day> to apply for days of the week or for one specific day of the month as follows:
Use a bitmask to set the weekdays on which the configuration applies here. The daymap appears in the following
order: HoSaFrThWeTuMoSu. For example, enter 00000001 if the configuration is to apply every Sunday.
To set the configuration to apply on one specific day every month, enter the day of the month followed by a full
stop. For example, enter 15. if the configuration is to apply on the 15th of every month.
If the configuration is to apply every day, do not set
<day>.
26.10.04-00:00:00,iGATE810000: Calls: 19351 (29716) - Minutes: 46647 - ASR1: 65.12% - ASR(ext): 65.12% -
ASR(int): 65.30% - ACD: 144.63s
Do not configure both StatisticTimeReset and StatisticTime or StatisticTimeReset and
StatisticCounter together.