SIGNALING AND ROUTING FEATURES
CHAPTER 8
160
ECOTEL 3G 16.1. Revised: 1 March 2011.
MapAll<num>=<port><num> CNC
Example:
8.10.2 EXCLUSION FROM SIM MINUTES COUNTER
The keyword DDNC (daily duration not counted) will exclude the mapping entry from the minutes counter:
MapAll<num>=<port><num> DDNC
Example:
8.11 MISCELLANEOUS ROUTING METHODS
In the following scenarios it may occur that some call numbers must be routed with differing lengths or that some
call numbers may require additional number conversion:
Calls without a destination number
Connection to a PBX with an extension prefix
Routing based on the length of the destination number
8.11.1 ROUTING CALLS WITHOUT A DESTINATION NUMBER
Enter the following configuration in the
route.cfg if the ECOTEL must route calls that come in without a des-
tination number:
Restrict<port>=<pl>
MapAll<pl><num>=<port><num>
MapAll<pl>=<port>
Incoming calls from the configured port will be assigned a placeholder and then all calls beginning with the place-
holder will be routed to the placeholder’s placeholder’s mapping.
Example: In the following example, all calls from controller 9 are routed to controller 10, regardless of
whether a destination number appears in the setup:
8.11.2 ROUTING CALLS BASED ON EXISTENCE OF DESTINATION NUM-
BER
To route calls with a DAD differently from those without a DAD, you must activate the block feature in the
pabx.cfg and restart the system:
Block=1
MapAll030=26212030 CNC
MapAll030=26212030 DDNC
Restrict9=pl
MapAllpl=10