CONFIGURATION FILES
CHAPTER 5
88
ECOTEL 3G 16.1. Revised: 1 March 2011.
RequestTimeout=<sec>
Number of seconds during which the request is repeated if the Radius server does not respond.
RequestRetries=<count>
Number of packet retries sent at one time.
StopOnly=<mode>
When
yes is entered, only Accounting Request Messages with the status type stop are transmitted to the
Radius server.
AlwaysConnected=<mode>
Enter
No (default) to set the value for the field ConnectedTime to that of the field
DisconnectedTime in accounting-stop messages when the call was not connected.
CallingStationId=<num>
This parameter is used to set the calling station ID. The default setting is the OAD, but you can define any
calling station ID. To define a partial calling station ID, enter a
? for each digit. For example,
CallingStationId=??? will consist of the first three digits of the OAD.
CallType=<int>
Enter one of the following to define the call type:
3 = VoIP and telephony
2 = VoIP only
1 = Telephony only
FramedProtocol=<int>
Enter one of the following to define the framed protocol (see RFC 2865, Chapter 5.7):
1 = PPP
2 = SLIP
3 = AppleTalk Remote Access Protocol (ARAP)
4 = Gandalf proprietary SingleLink/MultiLink protocol
5 = Xylogics proprietary IPX/SLIP
6 = X.75 Synchronous
NasId=<string>
The string entered is used as network access server identifier attribute in access requests. If no string is en-
tered, the attribute will not be set (default).
Table 5.26 route.cfg: Radius Parameters (continued)
Radius Parameters