#RFSTS – Read current network Status in 3G network
1 - RRC_STATE_CONNECTING
2 - RRC_STATE_CELL_FACH
3 - RRC_STATE_CELL_DCH
4 - RRC_STATE_CELL_PCH
5 - RRC_STATE_URA_PCH
6 - RRC_STATE_WILDCARD
7 - RRC_INVALID
Note: RRC (LTE) - Radio Resource Control States are:
0 - RRC_IDLE
1 - RRC_CONNECTED
Temperature Monitor- #TEMPMON
#TEMPMON - Temperature Monitor
AT#TEMPMON
=
<mod>[,<urcmo
de>[,<action>[,<
GPIO>]]]
Set command sets the behavior of the module internal temperature monitor.
Parameters:
<mod>
0 - sets the command parameters.
1 - triggers the measurement of the module internal temperature, reporting the result in
the format:
#TEMPMEAS: <level>,<value>
where:
<level> - threshold level
-2 - Extreme temperature lower bound.
-1 - Operating temperature lower bound.
0 - normal temperature.
1 - Operating temperature upper bound.
2 - Extreme temperature upper bound.
(see Note 1)
<value> - actual temperature expressed in Celsius degrees.
Setting of the following optional parameters has meaning only if <mod>=0:
<urcmode> - URC presentation mode. (Default 1)
0 - It disables the presentation of the temperature monitor URC.
1 - It enables the presentation of the temperature monitor URC, whenever the module
internal temperature reaches either operating or extreme levels. The unsolicited
message is in the format:
#TEMPMEAS: <level>,<value>