EasyManuals Logo

Telit Wireless Solutions ME910C1 Series Reference Guide

Telit Wireless Solutions ME910C1 Series
233 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #123 background imageLoading...
Page #123 background image
AT Commands Reference Guide
80529ST10815A Rev.2– 2017-09-14
ReproductionforbiddenwithoutTelitCommunicationsS.p.A.writtenauthorization‐AllRightsReserved page123of233
where:
<level> and <value> are as before.
<action> - sum of integers, each representing the action to be done whenever the
module internal temperature reaches either operating or extreme levels (default is 1).
0 - (00) - No action.
1 - (01) - Activating of thermal mitigation according to thermal configuration file.
2 - (10) - Output pin <GPIO> is tied HIGH when operating temperature bounds are
reached; when the temperature is back to normal the output pin <GPIO> is tied LOW.
If this <action> is required, it is mandatory to set the <GPIO> parameter too.
3- (11) - This value contains <action=1> and <action=2> i.e. activate thermal
mitigation and a GPIO indication. If this <action> is required, it is mandatory to set the
<GPIO> parameter too.
<GPIO> - GPIO number. Valid range is any TGPIO pin as described in #GPIO
command. This parameter is needed and required only if <action>=2 or 3 are enabled.
AT#TEMPMON
?
Read command reports the current parameter settings for #TEMPMON command in
the format:
#TEMPMON: <urcmode>,<action> [,<GPIO>]
AT#TEMPMON
=?
Test command reports the supported range of values for parameters <mod>,
<urcmode>, <action>, and <GPIO>
Notes
1. Thresholds levels are defined in #TEMPCFG command. See there for detailed
description on thermal mitigation configuration.
2. Last <action> setting is saved in the 'config.ini' file ('mitigate'/'none mitigate'),
and in the NVM ('gpio indication'/'none gpio indication').
3. Last <GPIO> is saved in the NVM.
4. Thermal mitigation is disabled automatically when using laboratory test SIM.
Temperature Monitor CONFIGURATION - #TEMPCFG
#TEMPCFG – Temperature Monitor Configuration
AT#TEMPCFG=
<etlz_clr>,<etlz>,<etlz_act_in>,<otlz
_clr>,<otlz>,<otlz_act_in>,<otnz_clr
>,<otnz>,<otnz_act_in>,<otuz_clr>,
<otuz>,<otuz_act_in>,<etuz_clr>,<e
tuz>,<etuz_act_in>
Set command sets the Temperature zones used in the
#TEMPMON command.
Parameters:
<etlz_clr>: Extreme low zone temperature threshold clear. Has
only one valid value: -273°C. see notes
<etlz>: Extreme low zone temperature threshold. Default
value -33°C.
<etlz_act_in>: Extreme low zone action info. Default value 0.
<otlz_clr>: Operate low zone temperature threshold clear.
Default value -35°C.

Table of Contents

Other manuals for Telit Wireless Solutions ME910C1 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions ME910C1 Series and is the answer not in the manual?

Telit Wireless Solutions ME910C1 Series Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelME910C1 Series
CategoryWireless modules
LanguageEnglish

Related product manuals