AT Commands Reference Guide
80529ST10815A Rev.2– 2017-09-14
ReproductionforbiddenwithoutTelitCommunicationsS.p.A.writtenauthorization‐AllRightsReserved page124of233
<otlz>: Operate low zone temperature threshold. Default
value -28°C.
<otlz_act_in >: Operate low zone action info. Default value 0.
<
otnz_clr>: Operate normal zone temperature threshold clear.
Default value -30°C.
<otnz>: Operate normal zone temperature threshold.
Default value 95°C.
<otnz_act_in>: Operate normal zone action info. Default value
0.
<
otuz_clr>: Operate up zone temperature threshold clear.
Default value 93°C.
<otuz>: Operate up zone temperature threshold. Default
value 100°C.
<otuz_act_in>: Operate up zone action info. Default value 3.
<
etuz_clr>: Extreme up zone temperature threshold clear.
Default value 98°C.
<etuz>: Extreme up zone temperature threshold. Has only
one valid value: 528°C.
see notes
<etuz_act_in
>: Extreme up zone action info. Default value 3.
See notes for detailed description of thermal mitigation
configuration.
AT#TEMPCFG?
Read command reports the current parameter setting for
#TEMPCFG command in the format:
#TEMPCFG:
<etlz_clr>,<etlz>,<etlz_act_in>,<otlz_clr>,<otlz>,<otlz_act_i
n>,<otnz_clr>,<otnz>,<otnz_act_in>,<otuz_clr>,<otuz>,<otu
z_act_in>,<etuz_clr>,<etuz>,<etuz_act_in>
AT#TEMPCFG =?
Test command reports the supported range values for parameters
<x
_clr>,<x>,<x_action_info>.
Where "x" is substitute for "
etlz", "otlz", "otnz", "otuz", "etuz".
Values are:
#TEMPCFG: (-40-100),(-40-100),(0-5)
Notes:
After setting new values, there must be an execution of power cycle or #REBOOT command in order for the
mitigation algorithm to operate with them.
Thermal mitigation mechanism works like this:
• The whole temperature scale is divided into 5 states (zones).
• Each measured temperature should be belonging to a particular state called the "
current state".
State is defined by the following fields:
- "
thresholds" – upper temperature boundary of the state. Values are in °C.

Table of Contents

Other manuals for Telit Wireless Solutions ME910C1 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions ME910C1 Series and is the answer not in the manual?

Telit Wireless Solutions ME910C1 Series Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelME910C1 Series
CategoryWireless modules
LanguageEnglish

Related product manuals