+CMEE - Report Mobile Equipment Error
Parameter:
<n> - enable flag
0 - disable
+CME ERROR:<err> reports, use only ERROR
report.
1 - enable
+CME ERROR:<err> reports, with <err> in
numeric format
2 - enable
+CME ERROR: <err> reports, with <err> in
verbose format
Note: default value after powerup is "0"
AT+CMEE?
Read command returns the current value of subparameter
<n>:
+CMEE: <n>
AT+CMEE=?
Test command returns the range of values for subparameter <n>
Note
+CMEE
has no effect on the final result code +CMS
Reference