181 Programmable Hardware Manual (PHM)
© Tibbo Technology Inc.
I1
(input)
Data line for input 1
W0&1 input for Wiegand reader 1
Clock input for clock/data reader 1
GPIO17/
W0&1in1/
cin1
35
I2
(input)
Data line for input 2
W1 input for Wiegand reader 1
Data input for clock/data reader 1
GPIO10/
W1in1/
din1
21
I3
(input)
Data line for input 3
W0&1 input for Wiegand reader 2
Clock input for clock/data reader 2
GPIO18/
W0&1in2/
cin2
37
I4
(input)
Data line for input 4
W1 input for Wiegand reader 2
Data input for clock/data reader 2.
GPIO12/
W1in2/
din2
25
I5
(input)
Data line for input 5
GPIO40
6
I6
(input)
Data line for input 6
GPIO41
8
I7
(input)
Data line for input 7
GPIO42
10
I8
(input)
Data line for input 8
GPIO43
12
C1
(output)
Channels 1 and 2 mode:
LOW - separate use or clock/data
i/f
HIGH - Wiegand i/f
GPIO1
3
C2
(output)
Channels 3 and 4 mode:
LOW - separate use or clock/data
i/f
HIGH - Wiegand i/f
GPIO2
5
Relay control
For all relay control lines:
HIGH (or input*) - relay off
LOW - relay on
For more information see Relays.
Line
Function
Corresponding
EM1000 I/O
IC1000 cable
line
RELAY1 (output)
Relay 1 control
GPIO32
30
RELAY2 (output)
Relay 2 control
GPIO33
28
RELAY3 (output)
Relay 3 control
GPIO34
26
RELAY4 (output)
Relay 4 control
GPIO35
24
RELAY5 (output)
Relay 5 control
GPIO36
22
RELAY6 (output)
Relay 6 control
GPIO37
20
*GPIO line configured as input (default state)
RS232/485 port control