1 NOMENCLATURE AND FUNCTIONS
1.14Rotating Method
1.14.1Rotating by H/V Shuttle and H/V Jog
H/V shuttle or H/V jog can be used to rotate the instrument manually. The shuttle movement or
displacement is proportional in speed and size of angle desired. A small, slow turn of the shuttle will
result in a slow small angle displaced. Likewise, a larger abrupt turn of the shuttle will result in a coarse
angle displacement. H/V jog can be used for accurate collimating of the target much like a standard
tangent screw.
*1)The mark will not appear.
1.14.2Auto Inversion
Pressing the Auto-Inversion icon in Star Key mode causes the instrument to reverse and turn the
telescope and instrument automatically.
To stop auto rotating by auto inversion key in case of emergency, press any keys except POWER
key.
During auto rotation, don't disturb the instrument.(Stopping the rotation with a touch of the hand).
Such action may cause trouble or harm to instrument or operator.
For further instructions, See Section 1.11 “Star Key Mode” .
1.14.3Rotating automatically to a required Horizontal and Vertical angle
In Standard Measurement Modes, the instrument can be rotated automatically by input a required
horizontal and/or vertical angle.
For further instructions, see Section 4.2.5 “Automatic Rotation to a Required Horizontal and Vertical
Absolute Angle” .
This mark will appear while the
instrument is rotating automatically. *1)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Topcon IS Series and is the answer not in the manual?

Topcon IS Series Specifications

General IconGeneral
BrandTopcon
ModelIS Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals