EasyManua.ls Logo

Toshiba TOSVERT VF-AS3 - Page 227

Toshiba TOSVERT VF-AS3
622 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E6582062
5-61 5. [Fundamental operation] How to use parameters
3
4
5
9
5. 3. 10 Automatic setting of main parameters by region
used
<SEt: Region setting check>
Function
When you select a region using in the setup menu at initial Power on, parameters such as the base
frequency of the motor is set automatically according to the selected region.
You can check the region that has been set or reset it by starting the setup menu.
Parameter setting
Selecting a setting value
0: Setup menu starting
The setup menu to select the region where the inverter is used is started.
When you select the region, parameters such as the base frequency and the base frequency
voltage of the motor that are described on the separate table are automatically set.
WARNING
Mandatory
action
Make sure to set the setup menu correctly.
If you set the setup menu incorrectly, this will damage the inverter or cause the inverter to
perform unexpected movement.
Title Parameter name Adjustment range
Default
setting
SEt Region setting check 0: Setup menu starting
1: Japan (read only)
2: Mainly North America (read only)
3: Mainly Asia (read only)
4: Mainly Europe (read only)
5: Mainly China (read only)
0
0: Setup menu starting
1: Japan
2: Mainly North America
3: Mainly Asia
0.0HzSTOP
15:23
SEt :Region Setting check
4: Mainly Europe
Basic parameter

Table of Contents

Other manuals for Toshiba TOSVERT VF-AS3

Related product manuals