E6582062
6. [Advanced] How to use parameters 6-22
4
4
6
9
F210 RX point 1 input value -100 to +100 % 0
F211 RX point 1 frequency 0.0-590.0 Hz 0.0
F212 RX point 2 input value -100 to +100 % 100
F213 RX point 2 frequency 0.0-590.0 Hz
50.0/60.0
*1
F214 RX point 1 rate -250 to +250 % 0
F215 RX point 2 rate -250 to +250 % 100
F216 II point 1 input value 0-100 % 0
F217 II point 1 frequency 0.0-590.0 Hz 0.0
F218 II point 2 input value 0-100 % 100
F219 II point 2 frequency 0.0-590.0 Hz
50.0/60.0
*1
F220 II point 1 rate 0-250 % 0
F221 II point 2 rate 0-250 % 100
F222 AI4 point 1 input value -100 to +100 % 0
F223 AI4 point 1 frequency 0.0-590.0 Hz 0.0
F224 AI4 point 2 input value -100 to +100 % 100
F225 AI4 point 2 frequency 0.0-590.0 Hz
50.0/60.0
*1
F226 AI4 point 1 rate -250 to +250 % 0
F227 AI4 point 2 rate -250 to +250 % 100
F228 AI5 point 1 input value -100 to +100 % 0
F229 AI5 point 1 frequency 0.0-590.0 Hz 0.0
F230 AI5 point 2 input value -100 to +100 % 100
F231 AI5 point 2 frequency 0.0-590.0 Hz
50.0/60.0
*1
F810 Communication
frequency point select
0: Disabled
1: RS485 (1)
2: RS485 (2)
3: Communication option
4: Embedded Ethernet
0
F811 Communication point 1
input value
0-100 % 0
F812 Communication point 1
frequency
0.0-FH Hz 0.0
F813 Communication point 2
input value
0-100 % 100
F814 Communication point 2
frequency
0.0-FH Hz
50.0/60.0
*1
*1 Depending on the setup menu. Refer to [11. 10].
Title Parameter name Adjustment range Unit Default setting