E6582062
6-103 6. [Advanced] How to use parameters
3
4
6
9
6. 24. 4 Selecting stall operation during regeneration
<F453: Stall operation during regen>
Function
This function is one of the functions to prevent the lifting gear from being displaced at stop. If current
stall prevention gets active during regeneration of controlled stop, there may be a mismatch at stop.
Set to inhibit only the stall prevention of current.
Parameter setting
Selecting a setting value
To inhibit the stall prevention of current during regeneration of controlled stop, set <F453: Stall
operation during regen> to "1".
Title Parameter name Adjustment range Default setting
F453 Stall operation during
regen
0: Enabled
1: Disabled
0
Reference
How to operate the operation panel -> Refer to [3. 1. 1].
How to switch display mode on the operation panel -> Refer to [3. 1. 2].
Procedure to change parameter setting -> Refer to [4. 2. 3]
0: 0: Enabled
1: 1: Disabled
0.0HzSTOP
13:46
F453 : Stall operation during regen

Table of Contents

Other manuals for Toshiba TOSVERT VF-AS3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS3 and is the answer not in the manual?

Toshiba TOSVERT VF-AS3 Specifications

General IconGeneral
ModelTOSVERT VF-AS3
CategoryInverter
Overload Capacity150% for 60 seconds
Cooling MethodForced Air Cooling
Control MethodV/f control, Sensorless vector control
Braking UnitBuilt-in
Communication ProtocolsModbus RTU, DeviceNet, Profibus DP
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Ground Fault
EnclosureIP20
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m

Related product manuals