E6582062
6. [Advanced] How to use parameters 6-182
4
4
6
9
When <F295: Bumpless> is set to "1: Enabled", the mode can be switched even during run.
In manual, the [EASY] key lamp or is lit .
In automatic, the inverter is operated with the operation method selected with <CMOd: Run
command select>, <FMOd: Frequency command select 1>, etc.
3: Monitor peak and minimum hold trigger
Set the peak hold and minimum hold triggers of <F709: Hold function of standard mode> with the
[EASY] key.
The measurement of the minimum and maximum values set for <F709> starts at the instant when
you press the [EASY] key after setting <F750: EASY key function> to "3".
The peak hold and minimum hold values are displayed in absolute values.
Memo
Note that when you set <F750> to "0" in manual, the panel operation status remains and the
setting is different from the one with <CMOd: Run command select>.
Reference
How to operate the operation panel -> Refer to [3. 1. 1].
How to switch display mode on the operation panel -> Refer to [3. 1. 2].
Procedure to change parameter setting -> Refer to [4. 2. 3]
<F295: Bumpless> of parameter -> Refer to [6. 13]
<F709: Hold function of standard mode> of parameter -> Refer to [6. 34. 7]
Auto
(Remote)
Hand
(Operation panel)
EASY
Moves to Hand (panel run).
When bumpless function is selected,
remote operation status remains.
Moves to Auto (remote).
(The operation status does not
remain even if bumpless function is
selected.)

Table of Contents

Other manuals for Toshiba TOSVERT VF-AS3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS3 and is the answer not in the manual?

Toshiba TOSVERT VF-AS3 Specifications

General IconGeneral
ModelTOSVERT VF-AS3
CategoryInverter
Overload Capacity150% for 60 seconds
Cooling MethodForced Air Cooling
Control MethodV/f control, Sensorless vector control
Braking UnitBuilt-in
Communication ProtocolsModbus RTU, DeviceNet, Profibus DP
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Ground Fault
EnclosureIP20
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m

Related product manuals