E6582062
6. [Advanced] How to use parameters 6-172
4
4
6
9
6. 34. 7 Holding display in [Standard mode]
<F709: Hold function of standard mode>
Function
The display in [Standard mode] can be held.
Parameter setting
Selecting a setting value
0: Real time
The contents selected with <F710: Standard mode display> are displayed.
1: Peak hold
2: Minimum hold
For peak hold values and minimum hold values, the maximum/minimum values in each operation
cycle are displayed.
When the motor is at a standstill, the values monitored last are held as they were until the motor is
started the next time.
The maximum and minimum values monitored after power is on are always displayed whether the
motor is running or at a standstill.
Title Parameter name Adjustment range Default setting
F709 Hold function of standard
mode
0: Real time
1: Peak hold
2: Minimum hold
0
Reference
How to operate the operation panel -> Refer to [3. 1. 1].
How to switch display mode on the operation panel -> Refer to [3. 1. 2].
Procedure to change parameter setting -> Refer to [4. 2. 3]
Details on operation by external signals -> Refer to [Chapter 7].
1: Peak hold
2: Minimum hold
0.0HzSTOP
14:13
0: Real time
F709 : Standard mode hold