8. Monitoring operation status 8-10
4
4
8
9
8. 1. 2 Detailed display of past trip
When you press the [OK] key while Past trip 1 to 8 are displayed in [Monitor mode], more detailed infor-
mation can be displayed as follows.
Unlike "Display at the time of trip" in [3. 2. 2], it can be displayed after the inverter is turned off or reset.
However, the monitor value of a trip is not always recorded as the maximum value because of the time
required for detection.
Details of the past
On the detail screen of the past trip show the information of the 13 items.
The trip history number and trip name are displayed in the mode name area.
Number of occurrences
Output frequency
Direction of rotation
Frequency command value
Output current
Input voltage (DC detection)
Output voltage
Input terminal 1 (F, R, RES, S1...S4, S5)
Output terminal 1 (FP, FL,R1, R2)
Cumulative operation time
•Year
Month, Date
Hour, Minutes
At following circumstance, the trip date (year, month, …) are
not correct.
1. LCD keypad is not attached.
2. date (year, month, …) are not set correctly.
3. the battery of LCD keypad is empty.
Output terminal 1 : FP,FL,R1,R2
Cumulative run time
Year
Month . Day
Hour . Minute
Top Return
10.0HzSTOP
14:16
Past trip 1 Cooling FAN fault
0.00
2015
7.13
13.06