E6582062
11-13 11. Table of parameters
1
3
9
10
11
F256 0256
Run sleep detection
time
0.0: Disabled
0.1 - 600.0
s 0.0 Y [6. 9]
F257 0257
Parameter for
manufacturer
------
F258 0258
Parameter for
manufacturer
------
F259 0259
Run sleep detection
time at startup
0.0: Disabled
0.1 - 600.0
s 0.0 Y [6. 9]
F260 0260 Jog frequency F240 - 20.0 Hz 5.0 Y
[6. 10]
F261 0261 Jog stop select
0: Deceleration stop
1: Coast stop
2: DC braking stop
--0N
F262 0262 Panel jog run
0: Disabled
1: Enabled
--0Y
F264 0264
Terminal Up
response time
0.0 - 10.0 s 0.1 Y
[6. 6. 5]
F265 0265
Terminal Up
frequency step
0.0 - FH Hz 0.1 Y
F266 0266
Terminal Down
response time
0.0 - 10.0 s 0.1 Y
F267 0267
Terminal Down
frequency step
0.0 - FH Hz 0.1 Y
F268 0268
Initial Up/Down
frequency
LL - UL Hz 0.0 Y
F269 0269
Up/Down frequency
rewrite
0: F268 is not changed.
1: F268 is changed after
power off.
--1Y
F270 0270 Jump frequency 1 0.0 - FH Hz 0.0 Y
[6. 11]
F271 0271
Jump frequency 1
band
0.0 - 30.0 Hz 0.0 Y
F272 0272 Jump frequency 2 0.0 - FH Hz 0.0 Y
F273 0273
Jump frequency 2
band
0.0 - 30.0 Hz 0.0 Y
F274 0274 Jump frequency 3 0.0 - FH Hz 0.0 Y
F275 0275
Jump frequency 3
band
0.0 - 30.0 Hz 0.0 Y
F287 0287 Preset speed 8 LL - UL Hz 0.0 Y
[5. 3. 7]
[6. 28]
F288 0288 Preset speed 9 LL - UL Hz 0.0 Y
F289 0289 Preset speed 10 LL - UL Hz 0.0 Y
F290 0290 Preset speed 11 LL - UL Hz 0.0 Y
F291 0291 Preset speed 12 LL - UL Hz 0.0 Y
F292 0292 Preset speed 13 LL - UL Hz 0.0 Y
F293 0293 Preset speed 14 LL - UL Hz 0.0 Y
F294 0294
Preset speed 15 /
Forced run speed
LL - UL Hz 0.0 Y
[5. 3. 7]
[6. 12. 2]
[6. 28]
[6. 31]
Title
Communication
No.
Parameter name Adjustment range Unit
Minimum
setting unit
(Panel/
Communication)
Default
setting
Write
during
running
*6
User
setting
Reference