EasyManua.ls Logo

Toshiba TOSVERT VF-AS3 - Page 529

Toshiba TOSVERT VF-AS3
622 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E6582062
11-27 11. Table of parameters
1
3
9
10
11
F495 0495
Over modulation
ratio
90 - 120 % 104 N [6. 26. 2]
F498 0498
Parameter for
manufacturer
------
F499 0499
Parameter for
manufacturer
------
F500 0500 Acceleration time 2 0.0 - 6000 (600.0) s
*1
Y
[6. 27. 2]
F501 0501 Deceleration time 2 0.0 - 6000 (600.0) s
*1
Y
F502 0502 Acc/Dec pattern 1
0: Linear
1: S-Pattern 1
2: S-Pattern 2
--0Y
[6. 27. 1]
[6. 27. 2]
F503 0503 Acc/Dec pattern 2
0: Linear
1: S-Pattern 1
2: S-Pattern 2
--0Y
[6. 27. 2]
F504 0504
Panel Acc/Dec
select
1: Acc/Dec 1
2: Acc/Dec 2
3: Acc/Dec 3
4: Acc/Dec 4
--1Y
F505 0505
Acc/Dec switching
frequency 1
0.0: Disabled
0.1 - UL
Hz 0.0 Y
F506 0506
S-Pattern range at
Acc start
0 - 50 % 10 Y
[6. 27. 1]
[6. 27. 2]
F507 0507
S-Pattern range at
Acc completion
0 - 50 % 10 Y
F508 0508
S-Pattern range at
Dec completion
0 - 50 % 10 Y
F509 0509
S-Pattern range at
Dec start
0 - 50 % 10 Y
F510 0510 Acceleration time 3 0.0 - 6000 (600.0) s
*1
Y
[6. 27. 2]
F511 0511 Deceleration time 3 0.0 - 6000 (600.0) s
*1
Y
F512 0512 Acc/Dec pattern 3
0: Linear
1: S-Pattern 1
2: S-Pattern 2
--0Y
F513 0513
Acc/Dec switching
frequency 2
0.0: Disabled
0.1 - UL
Hz 0.0 Y
F514 0514 Acceleration time 4 0.0 - 6000 (600.0) s
*1
Y
F515 0515 Deceleration time 4 0.0 - 6000 (600.0) s
*1
Y
F516 0516 Acc/Dec pattern 4
0: Linear
1: S-Pattern 1
2: S-Pattern 2
--0Y
F517 0517
Acc/Dec switching
frequency 3
0.0: Disabled
0.1 - UL
Hz 0.0 Y
F519 0519
Unit of Acc/Dec
time
0: -
1: 0.01 s unit (0 after
execution)
2: 0.1 s unit (0 after
execution)
--0N
[5. 2. 4]
[6. 27. 2]
Title
Communication
No.
Parameter name Adjustment range Unit
Minimum
setting unit
(Panel/
Communication)
Default
setting
Write
during
running
*6
User
setting
Reference

Table of Contents

Other manuals for Toshiba TOSVERT VF-AS3