11. Table of parameters 11-64
1
9
11
32 33 E Emergency off trip ON: During emergency off trip ("E" is displayed)
[7. 2. 2]
34 35 RETRY During retry ON: During retry
36 37 PTNS Pattern operation end ON: All pattern operation end
[6. 28]
[7. 2. 2]
38 39 PIDL PID deviation limit
ON: Within the setting value of <F364: PID1 deviation upper-
limit>, <F365: PID1 deviation lower-limit>
[7. 2. 2]
40 41 RUN Run/Stop ON: During run or DC braking, OFF: During stop
42 43 HFL Serious failure
ON: At trip
*1
, OFF: Other than those trip above
44 45 LFL Slight failure
ON: At trip ("OC1", "OC2", "OC3", "OP1", "OP2", "OP3",
"OH", "OL1", "OL2", "OL3", "OLr")
OFF: Other than those trip above
46 47 CPSW1
Commercial power/
Inverter Switching 1
ON: For inverter run
48 49 CPSW2
Commercial power/
Inverter Switching 2
ON: For commercial power run
50 51 FAN During cooling fan run ON: During cooling fan run
[6. 30. 11]
[7. 2. 2]
52 53 JOG During jog run ON: During jog run
[7. 2. 2]
54 55 JBM During terminal run ON: During terminal run, OFF: Other than terminal run
56 57 COT
Cumulative run time
alarm
ON: Cumulative operation time is <F621: Cumulative run
time alarm > or more
[6. 30. 12]
[7. 2. 2]
58 59 COMOP
Communication option
communication time-out
ON: Time-out of communication option occurs (held until
reset)
[7. 2. 2]
60 61 FR Fwd/Rev run
ON: During reverse run, OFF: During forward run
* Command direction or OFF during stop
62 63 RDY1 Ready for run 1 ON: Run when frequency command is ON
64 65 RDY2 Ready for run 2 ON: Run when ST, RUN, or frequency command is ON
68 69 BR During brake ON: Brake, OFF: Break release
70 71 PAL During alarm or pre-alarm ON: Alarm or pre-alarm occuring
72 73 FSL During Fwd speed limit ON: <F426: Fwd speed limit level> or more (Torque control)
74 75 RSL During Rev speed limit ON: <F428: Rev speed limit level> or more (Torque control)
76 77 HLTH Inverter healthy output
Output while switching ON and OFF over at every 1 sec. (to
check inverter soundness)
78 79 COME
RS485 communication
time-out
ON:RS485 communication time-out
[6. 38. 1]
[7. 2. 2]
92 93 DATA1 Designated data bit 0 ON: bit0 of FA50 is ON, OFF: bit0 of FA50 is OFF
[7. 2. 2]
94 95 DATA2 Designated data bit 1 ON: bit1 of FA50 is ON, OFF: bit1 of FA50 is OFF
106 107 LLD1 Light load detection 1 ON: Under heavy load torque(<F335> to <F338>)
108 109 HLD Heavy load detection ON: Heavy load torque(<F335> to <F338>)or more
110 111 PTL
During positive torque
limit
ON: During positive torque limit
112 113 MTL
During negative torque
limit
ON: During negative torque limit
114 115 RCRY
For external relay of rush
current suppression
ON: For external relay of rush current suppression
116 117 FL4 Failure signal 4 ON: During trip (including retry waite time)
[6. 15. 3]
[7. 2. 2]
Function Number
Symbol Function Action
Reference
Positive
logic
Negative
logic