EasyManua.ls Logo

TSAT 3000 - 3.13.1 POW_WAKEUP_FIRST_TIME

Default Icon
124 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TSAT 3000 - Telemetry and data transfer via SATellite
TSAT 3000 Configuration Parameter Description, January 2013 Page 100 of 124
3.13.1 POW_WAKEUP_FIRST_TIME
Ver <= 31.0.1: Default 0, Range –1… 1440
Ver >= 31.1.0: Default 0, Range 0…10080
Ver <= 31.0.1
Not Used.
Ver >= 31.1.0
Controls SLEEP mode operation.
Used when the Main-Unit Power-Save function is enabled by POW_WAKEUP_INTERVAL >= 2.
To let the different RTs wake up to specified time(s) relative to NMS, HUB and RT real time,
this MIB variable will define the first
time Main-Unit is waked up. Range is 0…10080 [minutes]
(that is: 1 minute … 1 week). Some examples:
POW_WAKEUP_
FIRST_TIME
POW_WAKEUP_
INTERVAL
Main-Unit is waked up [hh:mm]
12 60 00:12 – 01:12 – 02:12 - - - 23:12
10 10 00:10 – 00:20 – 00:40 - - - 23:50
1 70 00:01 – 01:11 – 02:21 - - - 23:21
720 1440 12:00 – 12:00 (next day)
3605 10080 Wednesday 12:05 – Wednesday 12:05 (next week)
Default value 0 will make the CURRENT to be replaced by 60 x 12 + NET_RT_ADDRESS – 1.
That will make all RTs to wake up at different
times the first time:
- RT 1 will wake up 12:00
- RT 2 will wake up 12:01
- RT 40 will wake up 12:39

Table of Contents