132
8 List of Setting Items
132
List of Setting Items
Chapter
8
■Setting mode 4
Name
Initial
value
Setting range
Lock1
(soft)
Lock2
(soft)
LOCK
(SW)
Display
only
Communication
command
1 D/A output mode 00 00 to 21
◎
W50(R/W)
Test mode 0
2: 20mA fixed output
1: 4mA fixed output
0: Weight value linked
Output weight mode 0
1: Net weight
0: Gross weight
2 D/A zero output weight 000.00 0 to 99998
◎
W51(R/W)
3 D/A full scale setting 100.00 1 to 99999
◎
W52(R/W)
4 RS-232C/RS-485 I/F setting 10101 00000 to 61217
Baud rate selection 1
6: Printer mode
(only with RS-232C)
5: 115.2kbps
4: 56800bps
3: 3840
0bps
2: 19200bps
1: 9600bps
0: 4800bps
Character length 0 1: 8bits 0: 7bits
Parity bit 1
2: Even 1: Odd
0: None
Stop bit 0 1: 2bits 0: 1bit
Terminator 1
(With RS-232C)
7: Communication mode 6
6: Communication mode 5
5: Communication mode 4
4: Communication mode 3
3: Communication mode 2
2: Communication mode 1
1: Communication mode 0/
CR+LF
0: Communication mode 0/
CR
(With RS-485)
2: Modbus-RTU
1: Communication mode 0/
CR+LF
0: C
ommunication mode 0/
CR
5 ID setting 0000 0000 to 9999
◎
6 Transmission delay time 00 00 to 99
◎