66
6 Useful Functions
66
Useful Functions
Chapter
6
- Communication mode 4
Transmits gross weight once when outputting an automatic print command.
Ignore all R, W, and C commands.
- Communication mode 5
Transmits net weight once when outputting an automatic print command.
Ignores all R, W, and C commands.
- Communication mode 6
Transmits gross weight and net weight once when outputting an automatic print command.
Ignores all R, W, and C commands.
Transmission format 1 (20 bytes)
Transmission format 2 (20 bytes)
Transmission format 3 (23 bytes)
Refer to P.67"6-10-4.Transmission format" for details on the transmission format
and P.63"■ Automatic print command" for details on the automatic printing function.
Attention
Timing of continuous transmission
When transmission mode 1, 2 or 3 is selected, the remote continuous
transmissions are as follows, according to the communication baud rate
settings.
Communication baud rate Remote continuous transmission
115.2k bps
When the A/D convert rate is 500 times/sec, 250 times/sec
When the A/D convert rate is 100 times/sec, 100 times/sec
57600 bps
When the A/D convert rate is 500 times/sec, 125 times/sec
When the A/D convert rate is 100 times/sec, 100 times/sec
38400 bps 100 times/sec
19200 bps 50 times/sec
9600 bps 25 times/sec
4800 bps 12 times/sec
Key point