Communication Interfaces
VTK-TR-BA-072e-1 - User Manual MDS 358X Series
53 VALVE:AOPEN
This command initiates a dispensing cycle with the parameter combination
currently selected. Usually this is the working configuration (setup 0). But if
in the menu SCENARIO is ON (see
paragraph 4.5.5, page 35), then the
parameters of scenario 1 are chosen. If the select pins are activated (see
paragraph 7.8, page 68), the setup (or scenario) is determined by them.
Important Note!
In case you trigger a dispensing process in the Infinite Mode with this
command, you cannot stop it via the RS232C interface. You can only stop it
via the PLC interface or by pressing the [esc]-key on the MDC.
The system launches a dispensing cycle, using the
parameters given by the working configuration, scenario 1
or the select pins, respectively (for further information
about scenarios and the select pins, see
paragraph 7.9,
page 70). Usually this is the working configuration (setup 0).
But if in the menu SCENARIO is ON (see paragraph 4.5.5,
page 35
), then the parameters of scenario 1 are chosen. If
the select pins are activated, the setup (or scenario) is