Operation
VTK-TR-BA-072e-1 - User Manual MDS 358X Series
compression chamber (the cavity at the rear end of the nozzle insert). The
interval is adjustable in steps of 0.01 ms.
Delay (DL)
This waiting phase between two cycles is adjustable in steps of 0.1 ms, but it
is recommended to use at least 0.2 ms.
Needle Lift (NL)
This parameter describes the stroke of the tappet, compared to its full value
of 100 %. For the range between 81 % and 100 %, the valve works in bipolar
mode. The elevated temperature in this range reduces the average frequency
and the lifetime of the valve. A needle lift between 70 % and 80 % is the best
working range.
Tab. 20: Parameters for dispensing