EasyManua.ls Logo

Vermes MDS 358X - Explanations

Default Icon
183 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Communication Interfaces
88
VTK-TR-BA-072e-1 - User Manual MDS 358X Series
8.1.2.2 Explanations
0
1 *ESR? ESR? = Event Status Register Query
Description:
This command shows the latest error codes created by the system, starting
with the latest event. At the most 50 error messages will be shown.
Each error messages also includes the valve ID (if known) and a time and
date stamp. If the RTC of the MDC is defect, the value will be given as
“00:00:00 2014-01-01”.
Example:
Input:
*ESR?
Result:
List of the (up to 50) latest error messages
Return:
8 199 valve error 08FU04 09:16:38 2018-01-21
9 101 wrong valve 08FU04 09:16:21 2018-01-21
2 *ESR2? ESR2? = Event Status Register Query 2
Description:
This command shows the latest error codes created by the system, starting
with the latest event. There will be shown a max of 50 error messages.
Each error messages also includes the valve ID (if known) and a time and
date stamp. If the RTC of the MDC is defect, the value will be given as
“00:00:00 2014-01-01”. Additionally the parameters of setups 0 to 3 before
the error are listed.
Example:
Input:
*ESR2?
Result:
List of the (up to 50) latest error messages with parameters
Return:
20 199 valve error 000000 09:16:38 2018-01-21
0, 0, 0, 0, 0, 0
0, 0, 0, 0, 0, 0
0, 0, 0, 0, 0, 0
0, 0, 0, 0, 0, 0
27 101 wrong valve 08FU04 09:16:21 2018-01-21
30, 5, 30, 80, 1, 20
50, 20, 20, 80, 1, 100
50, 20, 20, 80, 1, 100
50, 20, 20, 80, 1, 100
3 *IDN? IDN? = Identification Query
Description:
Device specific information, formatted as follows: type (hv or lv, high
viscosity or low viscosity systems), software version. Important for contact
with our Technical Support.
Example:
Input:
*IDN?
Result:
Micro Dispenser HV, 4085AA1-1
Return:
Micro Dispenser HV, 4085AA1-1
4 *OPC? OPC? = Operation Complete Query
Description:
Monitoring the last trigger impulses. After this, the counter is cleared to
zero.
Example:
Input:
*OPC?
Result:
Number of the last pulses. Clears the counter to zero.
Return:
6699

Table of Contents