66
VTK-TR-BA-072e-1 - User Manual MDS 358X Series
7.4 Minimum and Maximum Parameter Limits
Parameters Min. Value Max. Value Transform. Factor
(serial interface)
Rising
NL 1 % = RI 0.01 ms
NL 10 % = RI 0.03 ms
NL 20 % = RI 0.06 ms
NL 30 % = RI 0.09 ms
NL 40 % = RI 0.12 ms
NL 50 % = RI 0.15 ms
NL 60 % = RI 0.18 ms
NL 70 % = RI 0.21 ms
NL 80 % = RI 0.24 ms
NL 90 % = RI 0.27 ms
NL 100 % = RI 0.30 ms
300 ms
*10 or *100
e.g.
RI = 0.5 ms 5
or
RI = 0.05 ms 5
(Depends on the
command. See the
command description in
paragraph 8.1.2.2,
page 88.)
Falling
NL 1 % = FA 0.01 ms
NL 10 % = FA 0.01 ms
NL 20 % = FA 0.02 ms
NL 30 % = FA 0.03 ms
NL 40 % = FA 0.04 ms
NL 50 % = FA 0.05 ms
NL 60 % = FA 0.06 ms
NL 70 % = FA 0.07 ms
NL 80 % = FA 0.08 ms
NL 90 % = FA 0.09 ms
NL 100 % = FA 0.10 ms
300 ms
*100
e.g.
FA = 0.08 ms 8
Open Time
0 ms
NL 1-80 % = 3000 ms
NL 81-100 % = 15 ms
*10
e.g.
OT = 2 ms 20
Needle Lift
1 %
100 %
*1
e.g.
NL = 50 % 50
Number of Pulses (NP)
1 pulse
32000 pulses
*1
e.g.
NP = 80 80
Delay
0.1 ms
1000 ms
*10
e.g.
DL = 5 ms 50
Heater
Target temperature
Depends on the
connected heater (a
maximum of 300 °C can
be set)
*1
Tab. 21: Minimum and maximum parameter limits