Communication Interfaces
108
VTK-TR-BA-072e-1 - User Manual MDS 358X Series
59 WRITE:LCD:<text> (LCD = Liquid-crystal display)
Description:
With this command, an ASCII text including up to 32 characters can be writ-
ten on the screen. All the letters appear in form of capital letters.
Example:
Input:
WRITE:LCD:Hello World
Result:
The display shows:
HELLO WORLD
Return:
OK
60 TAPPET:SET:<value>
Description:
This command allows you to decide on the number of cycles until the next
tappet maintenance. If no numerical selection is made, the value will be
“infinite”.
Example:
Input:
TAPPET:SET:500000
Result:
500000 cycles have been selected.
Return:
OK
61 TAPPET:CLEAR
Description:
The counter for tappet maintenance is cleared. This command is usually
entered at the end of the maintenance procedure.
Example:
Input:
TAPPET:CLEAR
Result:
Counter reset to “0”.
Return:
OK
62 NOZZLE:SET:<Value>
Description:
This command determines the number of cycles to be performed until the
next maintenance of the nozzle insert. If you do not enter any number, the
value is set as “infinite”.
Example:
Input:
NOZZLE:SET:500000
Result:
500000 cycles have been selected.
Return:
OK
63 NOZZLE:CLEAR
Description:
The content of the nozzle maintenance counter is erased.
Example:
Input:
NOZZLE:CLEAR
Result:
Counter reset to “0”.
Return:
OK

Table of Contents