Control Unit MDC
26
VTK-TR-BA-072e-1 - User Manual MDS 358X Series
Function Key Function
[]
-key
The screen moves one menu step back.
or
The cursor is shifted one position to the left.
or
A parameter is modified.
[]-key
The screen moves one menu step ahead.
or
The cursor is shifted one position to the right.
or
A parameter is modified.
The [F1]-key opens the valve, taking into consideration the current values for
“Rising” and “Falling”. The Needle Lift used is capped at 80 %. The valve remains
opened until the key is released. Maximum length: 2 min. Then the valve closes
automatically in order to protect the actuator.
If you start the control unit, while holding the
[F2]
-key, you have the option to
format the EEPROM. With [enter] you agree, with [esc] you skip this point and
reach the main menu just as normal. This function will only be necessary in
exceptional cases.
Important Note!
Settings for Scenarios will not be reset back to the factory settings. That is only
possible with the options “Scenario” and “Reset ALL” after entering the service code
1000 (see paragraph 4.5.6 "Submenu Service-Option", page 37).