Communication Interfaces
VTK-TR-BA-072e-1 - User Manual MDS 358X Series
46 TRIGGER:ASET:?
This command gives the values for the pulse parameters currently saved in
the RAM. The correct order of the values is:
Rising, Open Time, Falling, Needle Lift, Number of Pulses, Delay.
Parameters relating to time are indicated in 1/10 ms, except for “Falling”
and “Rising” which are given in 1/100 ms. If the valve is currently operated
in external mode, the value for “Open Time“ is “EXTERNAL“. In infinite
mode, the number of pulses is always “0”.
Information is given about the current cycle parameters.
Rising: 55 ≙ 0.55 ms (ms = milliseconds)
Open Time: 10 ≙ 1.0 ms
Falling: 8 ≙ 0.08 ms
Needle Lift: 80 ≙ 80 %
Number of Pulses: 20