34
Familiarise yourself with the device
AutoPlus control unit messages
Bale densit y 90%
Indicates that 90% of the set
bale density has been rea-
ched.
A signal sounds to give notifi-
cation.
Bale density 100%
Indic ate s that the se t bale
dens ity ha s bee n re ac he d.
A signal sounds to give notifi-
cation.
“Start tying” is displayed. The
tying cy c le is runni ng.
The tying cycle was suc-
cessf ul . Op en t he re ar f lap v ia
the tractor control device. Ob-
serve the safety instructions
for operation.
The bale was ejected. Close
th e re ar f lap v ia t h e co nt rol de-
vice. Leave the control device
lev er in rear fla p clo sed p osi ti-
on for approximately 3 secon-
ds, to build up the pressure
for the defaul t bale dens ity.
Low battery voltage .
The battery voltage is under 9
volts. Check the tractor's po-
wer supply .
A signal sounds to give notifi-
cation.
Twi ne malf uncti on
The twine tying does not run.
A signal sounds to give notifi-
cation.
Observe the safety instruc-
tions »Maintenance« on page
86.
Net malfunction
The net tying does not run. A
signal sounds to give notifica-
tion.
Observe the safety instruc-
tions »Maintenance« on page
86.
Net motor malfuncti on
The net motor does not run.
A signal sounds to give notifi-
cation.
Observe the safety instruc-
tions »Maintenance« on page
86.
The net was drawn in at the
wrong moment.
A signal sounds to give notifi-
cation.
Observe the safety instruc-
tions »Maintenance« on page
86.