Remarks
A The send parameters bit (8) is set by the PLC after parameters have been changed
(for example, due to transmit parameters or a dimension change from the HMI)
B When the actuator becomes non-responsive, the reset actuator bit (9) can be used
to reset the actuator controller:
1. Set the reset actuator bit to '1' and wait for the busy bit to become '1' as well.
2. VVSX will reset the actuator and when the device is finished with resetting, the
busy bit will return to '0'.
3. Now remove the reset actuator command from the PLC.
C In case of a carcass conveyor;
The calibrate bit (13) switches off the centering of components, width measurement
is still enabled. Too wide and too narrow status bits (word 1, bits 10 and 11) will be
set in a normal fashion.
Commands from the PLC grafcets lead to a change of state in this register, signaling the
VVS system that new command data is available.