Station Programming 6-15
Default
DHS CO Lines (1-12) DAY ring for Station 10 only, all others are NONE, and DHS-E CO Lines
(700-705) BOTH ring for Station 100 only, all others are NONE. DHS CO range is 1-12 (D/N/
B/NONE). DHS-E CO range is 700-717 (D/N/B/NONE).
Account Code Forced
Any station in the system may be forced to use an Account Code when outgoing calls are
made. When this parameter is set to Y there must also be valid account codes
programmed into the Account Code Table. The Account Code entered at a station that is
Account Code - Forced will be verified against the table for a match. If a match is found
the outgoing call attempt is allowed, if not the call attempt is denied.
Default
DHS/DHS-E Account Code Forced is set to N (NO) for all stations.
Related Programming
Refer to Table 4-1: Feature Access Codes.
Station Groups
Stations may be assigned to one of eight available Station Groups. Station Groups dictate
what station page group and pick up group to which the station belongs.
Default
All DHS/DHS-E stations are assigned to Station Group 1, and the Station Group range is
from 1-8.
Warning Tone
Warning Tone may be applied to any station where outgoing call length is to be limited.
When set to Y this station will receive a warning tone over the connected voice path
when the Warning Time (refer to Call Handling Configuration) has expired. Once engaged,
the tone will be heard every 10 sec until the CO line call is terminated.
Default
DHS/DHS-E Warning Tone is set to N (NO) for all stations.
Related Programming
Refer to “Warning Time”, in the Call Handling Configuration section of this Chapter.
Receive Assignment must also be set to Y for a station to answer a ringing CO.