DHS-E Technical Specification Tables 3-11
Table 3-6: Maximum Cable Length
Digital Key Telephone
(Distance measures in linear feet of cable from KSU to DKT.)
26 AWG - 850 ft.
24 AWG - 1416 ft.
22 AWG - 1983 ft.
Standard Single Line Telephone
(Distance measures in linear feet of cable from KSU to SLT.)
(2-Port Analog Adapter may be placed anywhere in be-
tween.)
26 AWG - 650 ft.
24 AWG - 1133 ft.
22 AWG - 1586 ft.
Table 3-7: Dialing Specifications
DTMF Dialing mode:
Frequency deviation
Rise time
Duration of DTMF signal
Inter-digit time
VM Port DTMF duration
VM Port Inter-digit time
+
1%
3ms
programmable 50-150ms (70ms default)
programmable 50-150ms (70ms default)
programmable 60-150ms (120ms default)
programmable 60-150ms (120ms default)
Pulse Dialing mode:
Pulse dial rate
Pulse Make/Break ratio
10 pulses per second
60/40
Table 3-8: FCC Registration Numbers
For systems configured for Key System operation (each
CO line appears on its own dedicated button).
D6XTAI-25246-KF-E
For systems configured for hybrid operation (CO lines
may be accessed by dial codes and Pool/Loop buttons).
D6XTAI-25245-MF-E