Page: 5-4
WALKER MANUFACTURING COMPANY
July 2006
SERVICE INSTRUCTIONS
ELECTRICAL SYSTEM - MODEL MC
For troubleshooting, refer to Wiring Diagram.
IMPORTANT: Disconnect both battery cables before
unplugging any wiring connectors or making repairs on
the electrical system.
Circuit Breakers
A master circuit breaker is mounted on a bracket be-
hind the battery. The circuit breaker may have either
the manual or automatic reset function -- both types
have been used. See Circuit Breaker Location photo.
Circuit Breaker Location
ELECTRICAL SYSTEM - MODEL MS, MB
For troubleshooting, refer to the Wiring Diagram.
IMPORTANT: Disconnect both battery cables before
unplugging any wiring connectors or making repairs on
the electrical system.
30 Amp
Circuit Breaker
Circuit Breaker
Mounting Bracket