Permanent release means that the switching mechanism of
the reader is permanently switched without having to hold
a key in front of the reader again.
n The permanent release is activated by holding an author-
ised key in front of the reader for an extended period.
n Holding the key in front of the reader for an extended
period again deactivates the permanent release.
n A day-specific time at which the permanent release is
automatically deactivated can be defined in the reader
settings.
All instructions for the permanent release are available in
Ä
Chapter 7.5 “Add and manage reader” on page 100.
Action LED 1 (left) LED 2 (right) buzzer
Normal operation
(standby)
Yellow flashing O O
PR is switched on. Yellow flashing Constant green light O
Key with single
authorisation is pre-
sented. PR is deacti-
vated.
Single green light No change Single beep
Key with single
authorisation is pre-
sented. PR is active.
Single green light No change Single short beep
Key without authori-
sation is presented.
PR is deactivated.
Single red light No change Single long beep
Key without authori-
sation is presented.
PR is active.
Single red light No change Single short beep
Key with authorisation
for switching the PR is
presented for an
extended period of
time. PR is deacti-
vated.
Single green light Constant green light Two short beeps
Key with authorisation
for switching the PR is
presented for an
extended period of
time. PR is active.
Single green light O Two long beeps
Coding via Masterkey Yellow flashing No change O
Fault No change Constant red light O
Time is invalid. Constant red flashing No change O