Service Parts Disassembly
Phaser 3330 and WorkCentre 3335/3345 Xerox Internal Use Only
Service Manual
4-108
7. Release all of the catches from the back of the assembly.
8. Remove 3 screws (black, flanged, tap, 10 mm).
9. Release the catch under the assembly at the back.
CAUTION: Keep the platen assembly platen-side up to prevent the scanning mechanism from
falling out.
10. Unthread the wire harness and the ribbon cable that pass through the lower scan frame and
remove the A4 Middle Platen (Parts List 9.2 WorkCentre 3335/3345 Platen, PL 9.2.7).
11. Remove the platen glass (Parts List 9.2 WorkCentre 3335/3345 Platen, PL 9.2.5).