December 2006
4-27
WorkCentre M20, 4118, FaxCentre 2218 Family
REP 5.1
Repairs and Adjustments
8. Prepare to remove the MEA unit cover open, Figure 7.
NOTE: Removing the 4 screws that secure the guide - M scan assembly will ease the
removal of the MEA unit cover open.
Figure 7 Preparation
9. Remove the MEA unit cover open, Figure 8.
Figure 8 MEA unit - cover open removal
10. Remove the MEA unit guide duplex, Figure 9.
Figure 9 MEA unit guide duplex removal
1
Remove 4 screws.
Open the MEA unit - cover
open
1
Disconnect CN5 and 1 ground
harness.
3
Align the flat on the rear pivot with
the slot in the frame. Remove the
MEA unit - cover open from the rear
pivot, then the front pivot.
1
Remove the MEA unit
guide duplex.