Each Inneon PMIC controller is capable of reporng the voltage and current of its controlled rail
to the Inneon GUI for display to the user. Fourteen rails have a TI INA226 PMBus power
monitor circuit with connecons to the rail series current sense resistor. This arrangement
permits the INA226 to report the sensed parameters separately on the INA226_PMBUS. The
rails congured with the INA226 power monitors are shown in Table 25.
As described in I2C0 (MIO 14-15), the I2C0 bus provides access to the PMBus power controllers
and the INA226 power monitors through the U17 PCA9544A bus switch. All PMBus controlled
Inneon regulators are ed to the IRPS5401_SDA/SCL PMBUS, while the INA226 power
monitors are separated on to INA226_PMBUS.
Figure 7 and Table 10 document the I2C0 bus access path to the Inneon PMBus controllers and
INA226 power monitor op amps. Also refer to schemac 038-05003-01. Power rail
measurements are accessible to the system controller and RFSoC PL logic through their
respecve I2C0 bus connecons.
Chapter 3: Board Component Descriptions
UG1390 (v1.1) July 10, 2020 www.xilinx.com
ZCU216 Board User Guide 67