Note
The HIPI Ethernet interfaces use ETH1 and/or ETH2, not ETH0.
In case of 2 HIPI cards with IP only, there is no restriction in which camera is connected to which port.
A 16-camera network can be connected to a single port.
The HIPI card is automatically detected by the FastTrace 2 video system. Each HIPI card must be configured
with a different IP address and a subnet mask. As a consequence, 3 IP ranges are possible on a
FastTrace 2 configuration:
IP range of the FastTrace 2 video system
IP range of the first HIPI card
IP range of the second HIPI card
All IP cameras connected to the HIPI card (by means of a switch) must be set in the same IP range as the
HIPI card.