B95W
Description
82 / 306
5
05_Beschreibung_en.fm - V1.0 - 1.8.17
11
Level 3:
Warning
Active if: relative carbon black load is at approx. 110 %
“Particle filter regeneration” control light flashes quickly.
“Engine diagnosis” control light turns on.
Engine protection (warning level active) with a power reduction of 30 %.
Level 4:
Engine OFF
Active if: relative carbon black load is at approx. 125 %
“Particle filter regeneration” control light flashes quickly.
“Engine diagnosis” control light turns on.
Engine protection (Engine OFF level is active) with power reduction of 30 %, engine
speed is limited to 1200
rpm.
Level 5:
Filter change
Active if: relative carbon black load at > 156 %
Filter overload
If, despite the engine OFF message, the engine is still in operation and the
filter continues to accumulate load, regeneration is no longer possible.
At this point, the filter must be replaced.
The engine OFF level limits the engine speed to 1200 rpm.
Now, the machine is limited to ‘Limp home” functionality (limited driving).
Notice
In this state, the stoppage regeneration cannot be enabled by the driver
anymore.
At this point, the stoppage regeneration process can only by started using
SERDIA (engine diagnosis software from engine manufacturer DEUTZ).
Please contact Yanmar customer service.

Table of Contents