B95W
Description
05_Beschreibung_en.fm - V1.0 - 1.8.17
83 / 306
5
11
Monitoring the warning stages:
Tab. 5-8 Monitoring of warning stages
Engine exhaust
train protection
level
Filter load
[%]
Requirement for starting
regeneration
Regeneration
mode
Control light Engine/system
reaction
(when load is
excessive)
Particle filter
regeneration
Engine
diagnos-
tics
0
Normal < 63 - OFF OFF none
1
Heat mode 63 - Heat mode OFF OFF none
2
Stoppage
regeneration
100 - Park break locked
- Direction switch in
neutral
- Select “Particle filter
regeneration”
Stoppage Slow flashing
(2 second beat)
OFF none
3
Warning 110 - Park break locked
- Direction switch in
neutral
- Select “Particle filter
regeneration”
Stoppage Rapid flashing
(1 second beat)
TO Power reduction
30 %
4
Engine Off 125 - Park break locked
- Direction switch in
neutral
- Start using SERDIA
Stoppage Rapid flashing
(1 second beat)
Flashing Power reduction
30 %
- Engine speed
limited to 1200 rpm
5
Filter change 156 No regeneration
possible (=filter change)
regeneration
no longer
possible
Rapid flashing
(1 second beat)
Flashing Power reduction
30 %
- Engine speed
limited to 1200 rpm

Table of Contents