EasyManua.ls Logo

YASKAWA SGD7W - 12.2 Magnetic Contactors

YASKAWA SGD7W
337 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12.2 Magnetic Contactors
12-6
12.2
Magnetic Contactors
Use a Magnetic Contactor when you configure an external AC power supply sequence.
Note: Always attach a Surge Absorber (e.g., a Surge Absorber unit) to the excitation coil of the magnetic contactor.
Consult Fuji Electric FA Components & Systems Co., Ltd. for details.
Selection Table
Σ-7S SERVOPACKs
Σ-7W SERVOPACKs and Σ-7C SERVOPACKs
Main Circuit
Power
Supply
SERVOPACK
Order
Number
Inquiries
Maximum
Applicable Motor
Capacity [kW]
Model
SGD7S-
Three-phase,
200 VAC
0.05 R70A
SC-03
Fuji Electric FA
Components & Systems
Co., Ltd.
0.1 R90A
0.2 1R6A
0.4 2R8A
0.5 3R8A
0.75 5R5A
SC-4-11.0 7R6A
1.5 120A
2.0 180A
SC-5-1
3.0 200A
5.0 330A
SC-N1
6.0 470A
7.5 550A SC-N2
11 590A SC-N2S
15 780A SC-N3
Single-
phase,
200 VAC
0.05 R70A
SC-03
0.1 R90A
0.2 1R6A
0.4 2R8A
0.75 5R5A SC-4-1
1.5 120A
008 SC-5-1
Single-
phase,
100 VAC
0.05 R70F
SC-030.1 R90F
0.2 2R1F
0.4 2R8F SC-4-1
Main Circuit
Power
Supply
SERVOPACK
Order
Number
Inquiries
Maximum
Applicable Motor
Capacity [kW]
Model
SGD7W-
SGD7C-
Three-phase,
200 VAC
0.2 1R6A SC-03
Fuji Electric FA
Components & Systems
Co., Ltd.
0.75 2R8A
SC-4-1
0.75 5R5A
1.0 7R6A SC-5-1
Single-
phase,
200 VAC
0.2 1R6A SC-03
0.4 2R8A SC-4-1
0.75 5R5A SC-5-1

Table of Contents

Related product manuals