E.3 User Setting Table
620 YASKAWA ELECTRIC SIEP C710636 02B YASKAWA U1000 Technical Manual
L3-41
Vibration Suppression Gain during Deceleration (with
Current Limit)
L3-44
Current-limited Integral Time Constant during
Deceleration
L3-45
Current-limited Maximum S-curve Selection during
Deceleration
L4-01 Speed Agreement Detection Level
L4-02 Speed Agreement Detection Width
L4-03 Speed Agreement Detection Level (+/-)
L4-04 Speed Agreement Detection Width (+/-)
L4-05 Frequency Reference Loss Detection Selection
L4-06 Frequency Reference at Reference Loss
L4-07 Speed Agree Detection Selection
L5-01 Number of Auto Restart Attempts
L5-02 Auto Restart Fault Output Operation Selection
L5-04 Fault Reset Interval Time
L5-05 Fault Reset Operation Selection
L6-01 Torque Detection Selection 1
L6-02 Torque Detection Level 1
L6-03 Torque Detection Time 1
L6-04 Torque Detection Selection 2
L6-05 Torque Detection Level 2
L6-06 Torque Detection Time 2
L6-08 Mechanical Weakening Detection Operation
L6-09 Mechanical Weakening Detection Speed Level
L6-10 Mechanical Weakening Detection Time
L6-11 Mechanical Weakening Detection Start Time
L7-01 Forward Torque Limit
L7-02 Reverse Torque Limit
L7-03 Forward Regenerative Torque Limit
L7-04 Reverse Regenerative Torque Limit
L7-06 Torque Limit Integral Time Constant
L7-07
Torque Limit Control Method Selection during Accel/
Decel
L7-16 Torque Limit Process at Start
L8-02 Overheat Alarm Level
L8-07 Output Phase Loss Protection
L8-09 Output Ground Fault Detection Selection
L8-10 Heatsink Cooling Fan Operation Selection
L8-11 Heatsink Cooling Fan Off Delay Time
L8-12 Ambient Temperature Setting
L8-15 oL2 Characteristics Selection at Low Speeds
L8-18 Software Current Limit Selection
L8-19 Frequency Reduction Rate during Overheat Pre-Alarm
L8-27 Overcurrent Detection Gain
L8-29 Current Unbalance Detection (LF2)
L8-32 Cooling Fan Failure Selection
L8-35 Installation Method Selection
L8-38 Carrier Frequency Reduction Selection
L8-40 Carrier Frequency Reduction Off-Delay Time
L8-41 High Current Alarm Selection
L8-93 LSo Detection Time at Low Speed
L8-94 LSo Detection Level at Low Speed
L8-95 Average LSo Frequency at Low Speed
L9-03 Carrier Frequency Reduction Level Selection
L9-12 SoH Alarm Selection during bb
n1-01 Hunting Prevention Selection
n1-02 Hunting Prevention Gain Setting
n1-03 Hunting Prevention Time Constant
n1-05 Hunting Prevention Gain while in Reverse
n1-09 Vibration Suppression Level
n1-10 Suppression Frequency
n1-11 Suppression Auxiliary Frequency
n1-12 Vibration Suppression Time Constant
n2-01 Speed Feedback Detection Control (AFR) Gain
n2-02 Speed Feedback Detection Control (AFR) Time Constant 1
No. Name
User
Setting
n3-13 Overexcitation Deceleration Gain
n5-01 Feed Forward Control Selection
n5-02 Motor Acceleration Time
n5-03 Feed Forward Control Gain
n6-01 Online Tuning Selection
n6-05 Online Tuning Gain
n8-01 Initial Rotor Position Estimation Current
n8-02 Pole Attraction Current
n8-11 Induction Voltage Estimation Gain 2
n8-14 Polarity Compensation Gain 3
n8-15 Polarity Compensation Gain 4
n8-21 Motor Ke Gain
n8-35 Initial Rotor Position Detection Selection
n8-36 High Frequency Injection Level
n8-37 High Frequency Injection Amplitude
n8-39
Low Pass Filter Cutoff Frequency for High Frequency
Injection
n8-45 Speed Feedback Detection Control Gain (for PM Motors)
n8-47
Pull-In Current Compensation Time Constant (for PM
Motors)
n8-48 Pull-In Current (for PM Motors)
n8-49
d-Axis Current for High Efficiency Control (for PM
Motors)
n8-51 Acceleration/Deceleration Pull-In Current (for PM Motors)
n8-54 Voltage Error Compensation Time Constant
n8-55 Load Inertia
n8-57 High Frequency Injection
n8-62 Output Voltage Limit (for PM Motors)
n8-63 Output Voltage Limit Proportional Gain (for PM Motors)
n8-64 Output Voltage Limit Integral Time (for PM Motors)
n8-66
Output Voltage Limit Output Filter Time Constant (for PM
Motors)
n8-69 Speed Calculation Gain
n8-72 Speed Estimation Method Selection
n8-84 Polarity Judge Current
o1-01 Drive Mode Unit Monitor Selection
o1-02 User Monitor Selection After Power Up
o1-03 Digital Operator Display Selection
o1-04 V/f Pattern Display Unit
o1-05 LCD Contrast Control
o1-10 User-Set Display Units Maximum Value
o1-11 User-Set Display Units Decimal Display
o2-01 LO/RE (LOCAL/REMOTE) Key Function Selection
o2-02 STOP Key Function Selection
o2-03 User Parameter Default Value
o2-04 Drive Model Selection
o2-05 Frequency Reference Setting Method Selection
o2-06
Operation Selection when Digital Operator is
Disconnected
o2-07 Motor Direction at Power Up when Using Operator
o3-01 Copy Function Selection
o3-02 Copy Allowed Selection
o4-01 Cumulative Operation Time Setting
o4-02 Cumulative Operation Time Selection
o4-03 Cooling Fan Maintenance Operation Time Setting
o4-05 Capacitor Maintenance Setting
o4-07 DC Bus Pre-charge Relay Maintenance Setting
o4-11 U2, U3 Initialize Selection
o4-12 kWh Monitor Initialization
o4-13 Number of Run Commands Counter Initialization
o4-19 Power Unit Price
q1-01 to
q6-07
DriveWorksEZ Parameters
r1-01 to
r1-40
DriveWorksEZ Connection Parameter 1 to 20 (upper/
lower)
T1-00 Motor 1/Motor 2 Selection
T1-01 Auto-Tuning Mode Selection
No. Name
User
Setting
SIEP_C710636_02B_1_0.book 620 ージ 015年11月25日 水曜日 午後4時56