16-6
IM 765501-01E
16.2 Commands
16.2.1 A List of Commands
Command Function Page
Output Commands (OUTPut Group)
:OUTPut
[:STATe] 1|0|ON|OFF|ZERO Sets the output state (ON, OFF, or ZERO). 16-14
[:STATe]? Queries the output state (ON, OFF, or ZERO). 16-14
:PROGram 1|0|ON|OFF|PULSe Sets the programmable output state (ON or OFF) and executes pulse
generation. 16-14
:PROGram? Queries the programmable output state (ON or OFF). 16-14
Source Commands (SOURce Group)
:SOURce
:FUNCtion VOLTage|CURRent Sets the source function (voltage or current). 16-15
:FUNCtion? Queries the source function (voltage or current). 16-15
:SHAPe DC|PULSe Sets the source mode (DC or pulse). 16-15
:SHAPe? Queries the source mode (DC or pulse). 16-15
:MODE FIXed|SWEep|LIST Sets the source pattern (fixed level, sweep, or program sweep). 16-15
:MODE? Queries the source pattern (fixed level, sweep, or program sweep). 16-15
:DELay <Time>|MINimum|MAXimum Sets the source delay. 16-15
:DELay? [MINimum|MAXimum] Queries the source delay. 16-15
:PULSe
:WIDTh <Time>|MINimum|MAXimum
Sets the pulse width when generating pulse signals. 16-15
:WIDTh? [MINimum|MAXimum] Queries the pulse width when generating pulse signals. 16-15
:LIST
:SELect <String> Sets the program sweep pattern file. 16-16
:SELect? Queries the program sweep pattern file 16-16
:CATalog? Queries the list of program sweep pattern files. 16-16
:DELete <String> Deletes the program sweep pattern file. 16-16
:DEFine <String>,<String> Creates a program sweep pattern file. 16-16
:VOLTage
:RANGe <Voltage>|MINimum|MAXimum|UP|DOWN
Sets the voltage source range setting (200 mV, 2 V, 12 V, 20 V, 30 V,
60 V, or 110 V). 16-16
:RANGe? [MINimum|MAXimum] Queries the voltage source range setting (200 mV, 2 V, 12 V, 20 V, 30 V,
60 V, or 110 V). 16-16
:AUTO <Boolean> Sets the source auto range (ON or OFF). 16-16
:AUTO? Queries the source auto range (ON or OFF). 16-16
:LEVel <Voltage>|MINimum|MAXimum
Sets the voltage source level value. 16-17
:LEVel?[MINimum|MAXimum] Queries the voltage source level value. 16-17
:PBASe <Voltage>|MINimum|MAXimum
Sets the pulse base value for voltage pulse generation. 16-17
:PBASe? [MINimum|MAXimum] Queries the pulse base value for voltage pulse generation. 16-17
:PROTection
[:STATe] 1|0|ON|OFF Sets the limiter state (ON or OFF). 16-17
[:STATe]? Queries the limiter state (ON or OFF). 16-17
:LINKage 1|0|ON|OFF Sets the limiter tracking state (ON or OFF). 16-17
:LINKage? Queries the limiter tracking state (ON or OFF). 16-17
:ULIMit <Voltage>|MINimum|MAXimum
Sets the upper voltage limiter value (for generating current). 16-17
:ULIMit? [MINimum|MAXimum]
Queries the upper voltage limiter value (for generating current). 16-17