EasyManuals Logo

YOKOGAWA 765501 User Manual

YOKOGAWA 765501
277 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #178 background imageLoading...
Page #178 background image
16-6
IM 765501-01E
16.2 Commands
16.2.1 A List of Commands
Command Function Page
Output Commands (OUTPut Group)
:OUTPut
[:STATe] 1|0|ON|OFF|ZERO Sets the output state (ON, OFF, or ZERO). 16-14
[:STATe]? Queries the output state (ON, OFF, or ZERO). 16-14
:PROGram 1|0|ON|OFF|PULSe Sets the programmable output state (ON or OFF) and executes pulse
generation. 16-14
:PROGram? Queries the programmable output state (ON or OFF). 16-14
Source Commands (SOURce Group)
:SOURce
:FUNCtion VOLTage|CURRent Sets the source function (voltage or current). 16-15
:FUNCtion? Queries the source function (voltage or current). 16-15
:SHAPe DC|PULSe Sets the source mode (DC or pulse). 16-15
:SHAPe? Queries the source mode (DC or pulse). 16-15
:MODE FIXed|SWEep|LIST Sets the source pattern (fixed level, sweep, or program sweep). 16-15
:MODE? Queries the source pattern (fixed level, sweep, or program sweep). 16-15
:DELay <Time>|MINimum|MAXimum Sets the source delay. 16-15
:DELay? [MINimum|MAXimum] Queries the source delay. 16-15
:PULSe
:WIDTh <Time>|MINimum|MAXimum
Sets the pulse width when generating pulse signals. 16-15
:WIDTh? [MINimum|MAXimum] Queries the pulse width when generating pulse signals. 16-15
:LIST
:SELect <String> Sets the program sweep pattern file. 16-16
:SELect? Queries the program sweep pattern file 16-16
:CATalog? Queries the list of program sweep pattern files. 16-16
:DELete <String> Deletes the program sweep pattern file. 16-16
:DEFine <String>,<String> Creates a program sweep pattern file. 16-16
:VOLTage
:RANGe <Voltage>|MINimum|MAXimum|UP|DOWN
Sets the voltage source range setting (200 mV, 2 V, 12 V, 20 V, 30 V,
60 V, or 110 V). 16-16
:RANGe? [MINimum|MAXimum] Queries the voltage source range setting (200 mV, 2 V, 12 V, 20 V, 30 V,
60 V, or 110 V). 16-16
:AUTO <Boolean> Sets the source auto range (ON or OFF). 16-16
:AUTO? Queries the source auto range (ON or OFF). 16-16
:LEVel <Voltage>|MINimum|MAXimum
Sets the voltage source level value. 16-17
:LEVel?[MINimum|MAXimum] Queries the voltage source level value. 16-17
:PBASe <Voltage>|MINimum|MAXimum
Sets the pulse base value for voltage pulse generation. 16-17
:PBASe? [MINimum|MAXimum] Queries the pulse base value for voltage pulse generation. 16-17
:PROTection
[:STATe] 1|0|ON|OFF Sets the limiter state (ON or OFF). 16-17
[:STATe]? Queries the limiter state (ON or OFF). 16-17
:LINKage 1|0|ON|OFF Sets the limiter tracking state (ON or OFF). 16-17
:LINKage? Queries the limiter tracking state (ON or OFF). 16-17
:ULIMit <Voltage>|MINimum|MAXimum
Sets the upper voltage limiter value (for generating current). 16-17
:ULIMit? [MINimum|MAXimum]
Queries the upper voltage limiter value (for generating current). 16-17