16.2 Commands
Command Function Page
:LLIMit <Voltage>|MINimum|MAXimum
Sets the lower voltage limiter value (for generating current). 16-18
:LLIMit? [MINimum|MAXimum]
Queries the lower voltage limiter value (for generating current). 16-18
:SWEep
:SPACing LINear|LOGarithmic
Sets the sweep mode (linear or log) 16-18
:SPACing? Queries the sweep mode (linear or log) of the voltage sweep. 16-18
:STARt <Voltage>|MINimum|MAXimum
Sets the start value of the voltage sweep. 16-18
:STARt? [MINimum|MAXimum]Queries the start value of the voltage sweep. 16-18
:STOP <Voltage>|MINimum|MAXimum
Sets the stop value of the voltage sweep. 16-18
:STOP? [MINimum|MAXimum] Queries the stop value of the voltage sweep. 16-18
:STEP <Voltage>|MINimum|MAXimum
Sets the step value of the voltage sweep (linear sweep). 16-19
:STEP? [MINimum|MAXimum] Queries the step value of the voltage sweep (linear sweep). 16-19
:POINts <Integer>|MINimum|MAXimum
Sets the step count of the voltage sweep (log sweep). 16-19
:POINts? [MINimum|MAXimum]
Queries the step count of the voltage sweep (log sweep). 16-19
:ZERO
:IMPedance HIGH|LOW Sets the zero source impedance (high or low) for generating voltage. 16-19
:IMPedance? Queries the zero source impedance (high or low) for generating voltage. 16-19
:OFFset <Voltage> Sets the zero source offset value for generating voltage. 16-19
:OFFset? Queries the zero source offset value for generating voltage.
:CURRent
:RANGe <Current>|MINimum|MAXimum|UP|DOWN
Sets the current source range setting (2 µA, 200 µA, 2 mA, 20 mA,
200 mA, 0.5 A, 1 A, 2 A, or 3 A). 16-19
:RANGe? [MINimum|MAXimum] Queries the current source range setting (2 µA, 200 µA, 2 mA,
20 mA, 200 mA, 0.5 A, 1 A, 2 A, or 3 A). 16-19
:AUTO 1|0|ON|OFF Sets the source auto range (ON or OFF). 16-19
:AUTO? Queries the source auto range (ON or OFF). 16-20
:LEVel <Current>|MINimum|MAXimum
Sets the current source level value. 16-20
:LEVel? [MINimum|MAXimum] Queries the current source level value. 16-20
:PBASe <Current>|MINimum|MAXimum
Sets the pulse base value for generating current pulse. 16-20
:PBASe? [MINimum|MAXimum] Queries the pulse base value for generating current pulse. 16-20
:PROTection
[:STATe] 1|0|ON|OFF Sets the limiter state (ON or OFF). 16-20
[:STATe]? Queries the limiter state (ON or OFF). 16-20
:LINKage 1|0|ON|OFF Sets the limiter tracking state (ON or OFF). 16-20
:LINKage? Queries the limiter tracking state (ON or OFF). 16-20
:ULIMit <Current>|MINimum|MAXimum
Sets the upper current limiter value (for generating voltage). 16-21
:ULIMit? [MINimum|MAXimum]
Queries the upper current limiter value (for generating voltage). 16-21
:LLIMit <Current>|MINimum|MAXimum
Sets the lower current limiter value (for generating voltage). 16-21
:LLIMit? [MINimum|MAXimum]
Queries the lower current limiter value (for generating voltage). 16-21
:SWEep
:SPACing LINear|LOGarithmic
Sets the sweep mode (linear or log) 16-21